OEHLER

System 83

Overview, specifications and how to request a supply assessment and quote

Oehler Research · Ballistic Measurement Systems

Oehler System 83

An earlier-generation combined chamber pressure and velocity system. For new projects we recommend its successor, System 85.

System 83 is an earlier-generation Oehler ballistic system. It connects to a Windows computer over RS-232 and measures chamber pressure, muzzle velocity and downrange terminal velocity on the same shot. The pressure input is a 0–10V signal digitized at 10-bit resolution every 18 microseconds; the pressure curve appears right after the shot with peak pressure, area under the curve and rise time. Velocity comes from Model 57 infrared screens, up to 6 in total, 3 of which can sit downrange to measure terminal velocity and ballistic coefficient. Oehler now covers this ground with System 85 (pressure and velocity) and System 89 (exterior ballistics and BC), so new installations should go straight to those. Evencat can assess repair and calibration needs for existing System 83 equipment.

Overview

System 83 is housed in a 17" × 8" × 1.75" metal enclosure and talks to a Windows computer over RS-232. The pressure input accepts a 0–10V signal, digitized at 10-bit resolution at 18 microsecond intervals. The pressure curve is displayed as soon as the shot fires, with peak pressure, area under the curve and rise time computed. Velocity uses Model 57 infrared photoelectric screens, up to 6 of them, and 3 may be placed downrange to measure terminal velocity and derive ballistic coefficient. The acoustic target works with bullets faster than 1,500 fps. Machine-gun rate of fire is measured up to 2,000 rounds per minute. The model has been superseded by System 85 and System 89 and no longer appears in Oehler's current list of industrial systems. Evencat can help with repair, calibration and upgrade assessment of existing units, and with supply assessment of the successors.

Oehler System 83

Key specifications

ConstructionMetal enclosure 17" × 8" × 1.75", RS-232 to a Windows computer
Pressure measurement0–10V signal, 10-bit digitizing, 18 microsecond sample interval
Pressure outputPressure curve displayed right after the shot; peak pressure, area under curve, rise time
Velocity measurementModel 57 infrared photoelectric screens at the muzzle for instrumental velocity
Screen countUp to 6, including 3 downrange screens for terminal velocity and ballistic coefficient
Acoustic targetFor bullets faster than 1,500 fps
Machine-gun rateUp to 2,000 rounds per minute
StatusDiscontinued; succeeded by System 85 (pressure and velocity) and System 89 (exterior ballistics and BC)

Features

Pressure and velocity in one instrument

The pressure curve appears right after the shot, alongside muzzle and downrange velocity.

Up to 6 Model 57 screens

3 of them can be placed downrange to measure terminal velocity and derive ballistic coefficient.

Acoustic target support

For bullets at 1,500 fps and above.

Machine-gun rate to 2,000 rounds per minute

Rate-of-fire measurement for automatic weapons.

A clear succession path

System 85 takes over pressure and velocity, System 89 takes over exterior ballistics and BC, with no loss of function.

Configuration and maintenance

System 83 system configuration

Configuration · SETUP

Pressure plus multiple screens

Up to 6 Model 57 screens, 3 of them downrange to measure terminal velocity and derive ballistic coefficient.

Sensors · SCREENS

Model 57 as the standard input

Active infrared screens are unaffected by ambient light. They were the standard velocity sensor for System 83 and are still supplied today.

Model 57 infrared screen
Ballistic laboratory measurement bench

Laboratory

Ballistic laboratory

Chamber pressure, velocity and consistency measurement in indoor tunnels and labs, where data must flow straight into statistical analysis and QC reporting.

Quality control · QA

Ammunition production QC

Lot sampling and type approval need a repeatable measurement baseline; shot-by-shot archiving supports long-term trend tracking and traceability.

Production line quality control inspection

Options and configuration

System 83 is discontinued. This page stays up as a maintenance reference for existing equipment; for new projects ask us about the successors, System 85 / System 89.

Standard equipment (included)

Existing System 83 main unitMetal enclosure, RS-232 interface, combined pressure and velocity measurement.
Model 57 infrared screensMuzzle and downrange velocity, up to 6 screens.

Options and extensions

Service and support

0 options selected Standard configuration only
Add configuration to quote request

Downloads

This model is discontinued; the factory successor is System 85. New projects should go straight to the successor, and repair or calibration of existing units can be assessed separately. This product is a ballistic measurement system. Oehler restricts its international export and a US export license may be required. Evencat can submit an export assessment to the factory and obtain a supply and lead-time reply. Evencat supplies and quotes Oehler Research, Inc. (Austin, Texas, USA) products in Taiwan, with model selection advice, supply assessment and training.

Supplied and quoted by Evencat
Manufacturer technical support
Reply within 24 hours
Manufacturer warranty

Need pricing, specifications or lead time for system83?

Request a quote