OEHLER

Model 57

Overview, specifications and how to request a supply assessment and quote

Oehler Research · Sensors and Screens

Oehler Model 57

An active ballistic screen with its own infrared source: the standard sensor for indoor ranges, night work and low-light conditions.

The Model 57 is the complement to the sky-lit Skyscreen III. It carries its own infrared source, so it keeps working in an enclosed indoor range, at night, or under poor lighting, which makes it the standard sensor in ballistics laboratories. An infrared source runs along the top and several photodetectors sit in the base; when a projectile crosses the reference plane the screen outputs a nominal +12V pulse about 2 ms wide with a rise time of about 0.1 microsecond, so timing error is very small. It normally detects projectiles as small as .17 caliber at velocities as low as 250 fps, with sensitivity improving for larger projectiles and higher velocities. The System 83, Model 35BNC and Model 35x2 all use the Model 57 as their standard input. A low-velocity variant is available for larger, slower sporting balls and coefficient of restitution testing.

Overview

The point of the Model 57 is to put the light source inside the instrument so the measurement no longer depends on room lighting. The infrared source at the top shines down, the photodetectors in the base receive continuously, and a projectile crossing the reference plane breaks the beam and fires the output. That output is a nominal +12V pulse about 2 ms wide on a BNC connector, with a rise time of about 0.1 microsecond. Rise time decides how precisely the trigger instant is defined, and it is what qualifies the screen for laboratory work. Detection normally covers .17 caliber and up at velocities as low as 250 fps, with better sensitivity for larger projectiles and higher velocities, and automatic gain control compensates for dust in the light path. One practical rule for setup: for velocities below 1,200 fps, and for automatic fire, place a wooden blast shield between the muzzle and the first screen so muzzle flash is not read as a projectile. Units ship set for 120V AC at 50 or 60 Hz and can be changed to 240V operation, so they suit different national grids. The low-velocity variant handles larger, slower sporting balls and COR rebound testing. Evencat supplies and quotes the Model 57 in Taiwan.

Oehler Model 57

Key specifications

PrincipleInfrared source at the top, several photodetectors in the base; detects the projectile crossing the reference plane
CaliberGenerally .17 caliber and up; sensitivity improves with larger projectiles
Velocity floorNormally down to 250 fps (sensitivity improves with larger projectiles and higher velocities)
Low-velocity and automatic-fire noteBelow 1,200 fps, and for automatic fire, a wooden blast shield must be placed between the muzzle and the first screen
OutputNominal +12V pulse, about 2 ms wide, on a BNC connector
Rise timeAbout 0.1 microsecond
PowerShips set for 120V AC (50 or 60 Hz); convertible to 240V operation
OptionLow-velocity variant for larger, slower sporting balls and coefficient of restitution testing

Features

Active infrared source

Independent of room lighting; runs reliably in enclosed ranges and at night.

Down to .17 caliber and 250 fps

Covers everything from airguns to large-caliber rifles.

0.1 microsecond rise time

A sharply defined trigger instant and very small timing error, fit for laboratory measurement.

Standard BNC output

Easy to integrate with existing timers; the System 83, Model 35BNC and 35x2 all use it as standard input.

120V / 240V switchable power

Ships set for 120V AC at 50 or 60 Hz and converts to 240V, for use on different national grids.

Setup and applications

Model 57 screen setup layout

SETUP

Standard indoor range layout

First screen 5 or 10 ft from the muzzle, clear of muzzle blast, second screen 10 or 20 ft beyond it; below 1,200 fps or for automatic fire, add a wooden blast shield.

LABORATORY

Ballistics laboratory

Pressure, velocity and consistency measurement on indoor ranges, where data must flow straight into statistical analysis and QC reporting.

Ballistics laboratory bench
Production line quality control inspection

QUALITY CONTROL · QA

Ammunition production QC

Lot sampling and type approval need a repeatable measurement baseline; automatically filed shot data supports long-term trend tracking and traceability.

SPORTING GOODS · SPORTS

Sporting goods rebound testing

Coefficient of restitution (COR) is a key performance and compliance figure for golf, tennis and baseball equipment, and Taiwan is one of the world's main manufacturing bases.

Sporting goods performance and compliance testing

Options and configuration

Tick the items you need and we will compile the configuration into the inquiry form. Oehler products are quoted case by case by the manufacturer; lead time is as confirmed by Oehler.

Standard equipment (included)

Model 57 infrared screen unitInfrared source at the top, several photodetectors in the base.
BNC outputNominal +12V pulse, about 2 ms wide, rise time about 0.1 microsecond.
120V / 240V AC powerShips set for 120V, 50 or 60 Hz, convertible to 240V.

Options and add-ons

Service and support

0 options selected Standard configuration only
Add configuration to quote request

Downloads

Evencat supplies and quotes Oehler Research, Inc. (Austin, Texas, USA) products in Taiwan, and provides selection advice, supply assessment and training.

Supplied and quoted by Evencat
Manufacturer technical support
Reply within 24 hours
Manufacturer warranty

Need pricing, specifications or lead time for model57?