The 640N is a ruggedized failsafe igniter tester for military ordnance programs. It measures the resistance of explosive bridgewires (EBW), squibs, detonators and igniters without risk of firing them. A shielded Faraday cage and a waterproof rugged case make it suitable for rough field conditions. Evencat is AMPTEC's sole distributor in Taiwan.

Overview

The AMPTEC 640N is a ruggedized mid-range failsafe igniter tester developed for military ordnance and aerospace and defense work. It measures bridgewire resistance on squibs, igniters, explosive bolts, rocket motor squibs, automotive airbag initiators and other pyrotechnic devices without initiating them. A self-contained DC milliammeter and test resistors are built in, and four ranges of 20Ω, 2000Ω, 200KΩ and 2MΩ are provided. The shielded Faraday cage keeps external electromagnetic interference out, and the failsafe current is hard-limited to prevent accidental initiation. AMPTEC lists the 640N with multiple safety approvals, and it is catalogued under NSN 6625-01-642-8232. The waterproof rugged case carries a 4½ digit LED display and rechargeable NICAD batteries, giving field durability with laboratory-class accuracy (±.02% of reading & range). Note that the 641N and 641RS offer the same protection in a lighter case; the 640N remains the choice where an NSN or an existing procurement spec names it.

640N

Key specifications

Ranges20Ω / 2000Ω / 200KΩ / 2MΩ
Nominal current5 mA / 50 µA / 0.5 µA / 0.05 µA
Failsafe current8 mA / 150 µA / 1.5 µA / 0.15 µA (8 mA max)
Resolution1 mΩ / 10 Ω / 10 Ω / 100 Ω
Accuracy±.02% of reading & range (2MΩ range: ±1% of reading & ±.2% of range)
Display4½ digit LED
TerminalsTrident
Temperature coefficient±.002% per 15°C
Operating temperature0° to 50°C
Max input voltage / open circuit voltage250 VDC / 1.6 VDC
Power4 rechargeable 5AH NICAD batteries
Dimensions / weight13.4″ (L) × 11.62″ (W) × 6″ (D) / 9.8 lbs

Features

Failsafe design

The failsafe current is hard-limited (8 mA max), so squibs, detonators and explosive bridgewires cannot be initiated during measurement.

Shielded Faraday cage

A shielded Faraday cage keeps external electromagnetic interference out, for stable resistance readings in fuel-laden and electrically noisy areas.

Military-grade waterproof case

The waterproof rugged case is built for harsh field and ordnance work, standing up to the shock, water and dust of transport and deployment.

Four ranges

Ranges of 20Ω, 2000Ω, 200KΩ and 2MΩ with ±.02% of reading & range accuracy cover most igniter measurement needs.

Self-contained measuring system

A built-in DC milliammeter and test resistors, a clear 4½ digit LED display and rechargeable NICAD batteries support long sessions in the field.

Approvals

Built under ISO 9001:2015, UL-913 compliant, catalogued under NSN 6625-01-642-8232, and in service with NASA and the USAF.

Typical applications

640N pre-installation inspection of missile and rocket motor igniters

Munitions and ordnance

Pre-installation inspection of missile and rocket motor igniters

Before a missile system or rocket motor enters the final assembly line, ordnance technicians use the 640N to confirm the resistance of explosive bridgewires (EBW) and detonators is within design tolerance. The 8mA maximum failsafe current keeps the test from initiating the device and protects the assembly crew.

Aerospace ground support

Depot-level testing of spacecraft pyrotechnic separation systems

NASA and USAF ground support teams use the 640N on the pad or in the maintenance hangar for depot-level resistance measurements on pyrotechnic separation bolts and flare igniters. The waterproof ruggedized case and rechargeable NICAD batteries let it run on its own at an outdoor launch site with no external power.

640N depot-level testing of spacecraft pyrotechnic separation systems
640N non-destructive safety confirmation at an explosive ordnance disposal site

EOD and safe disposal

Non-destructive safety confirmation at EOD sites

When handling unexploded ordnance or recovered igniters in the field, EOD teams rely on the 640N's Faraday cage shielding and four ranges (20Ω to 2MΩ) for non-destructive resistance checks on fuze bridgewires. They confirm continuity or short-circuit risk while the induced current stays below the safe threshold, in line with UL-913 intrinsic safety rules.

Options and configuration

Tick the options you need; we will assemble the configuration list and carry it into the inquiry form.

Standard equipment (included)

4½ digit high-brightness LED display (20,000 counts)Readable in bright sunlight and in the dark
Four-range resistance measurement (20Ω / 2000Ω / 200kΩ / 2MΩ)All four ranges fitted as standard; nominal current 5mA, 50µA, 0.5µA and 0.05µA
Faraday cage designIsolates external RF and static so explosive bridgewire (EBW) tests stay safe
Built-in DC milliammeter and test resistorsSelf-contained; no external meter is needed to complete a test
Trident fork terminal inputThree-pin connector that cannot be plugged in the wrong way, matching military practice
4 rechargeable 5AH NiCAD batteriesLong field runtime with no mains supply
Waterproof ruggedized carry caseWaterproof ruggedized case for outdoor and harsh conditions
NSN 6625-01-642-8232Listed in the US federal supply catalog (NSN), which simplifies government procurement

Test lead and probe options

Charger option

0 options selected Standard configuration only
Add configuration to quote request

Downloads

Sole distributor in Taiwan
Manufacturer technical support
Reply within 24 hours
Manufacturer warranty

Need pricing, specifications or lead time for 640N?

Request a quote